An IK rating describes how well an electrical enclosure resists physical impacts. The system applies to a wide range of equipment, including light fittings, electrical cabinets and control panels. It helps you choose products for places where they could be knocked during everyday use, damaged during maintenance or exposed to vandalism.
In lighting, you will find IK ratings on products such as LED bulkheads, non-corrosive fittings, floodlights and ground lights. A higher rating means a higher level of impact resistance under standardised test conditions.
IK classifications are defined by IEC 62262, adopted in the UK as BS EN 62262. Each code corresponds to an impact-energy level measured in joules (J). The numbers are not a simple linear scale: IK10 represents four times the impact energy of IK08.
| IK rating | Impact energy | How it compares |
|---|---|---|
| IK06 | 1 joule | Lower impact resistance than the ratings below |
| IK07 | 2 joules | Twice the impact energy of IK06 |
| IK08 | 5 joules | A substantial increase over IK07 |
| IK09 | 10 joules | Twice the impact energy of IK08 |
| IK10 | 20 joules | Four times the impact energy of IK08 |
| IK11 | 50 joules | A higher classification included in the 2021 amendment |
These values describe controlled impact tests, rather than how many knocks a product can survive. For perspective, 20 joules is approximately the energy of a 5 kg mass falling 400 mm. It does not mean that every object dropped from that height will produce the same result.
Yes, if the requirement is a minimum of IK08. An IK10-rated fitting exceeds that impact-resistance level, so there is no need to restrict your search to IK08 when a suitable IK10 alternative is available.
The fitting must still meet the other requirements, including light output, dimensions, mounting, IP rating and any emergency or control functions. Where a project specifies a particular product, have the alternative accepted by the person responsible for the specification.
LED bulkheads: Accessible fittings in communal corridors, stairwells and exterior areas may be knocked or deliberately damaged. Both IK08 and IK10 options are available, with the higher rating providing greater rated impact resistance.
Non-corrosive fittings: In workshops, garages and industrial spaces, fittings may be struck by tools, ladders or materials being moved. Check the IK rating alongside the IP rating; the description “non-corrosive” does not establish an impact-resistance level.
Ground lights: Footwear, tools and garden equipment can all cause impacts. However, an IK rating does not establish walk-over or drive-over suitability. Check the manufacturer's stated load capacity and installation requirements separately.
Choose protection to suit the actual location and risk. A sheltered fitting mounted out of reach may have different needs from one beside a busy walkway.
Greater impact resistance can reduce the risk of damage and the cost and disruption of replacement. It is particularly useful where fittings are accessible or exposed to frequent activity. Where otherwise comparable products cost a similar amount, the higher rating offers useful additional protection.
However, IK10 does not mean indestructible or vandal-proof. Nor does it guarantee a longer LED or driver lifespan: the rating concerns the enclosure's resistance to specified impacts.
It can, but not automatically. Depending on the design, achieving greater impact resistance may involve thicker components, reinforcement or different materials. These changes can add cost and weight.
However, a high rating does not require a heavy metal housing. For example, Ansell's IK08 Sleek and IK10 ARX bulkheads both use polycarbonate construction. Material choice, shape and overall design all matter, so compare the actual product weights rather than judging by the IK code.
There is also no fixed price premium for IK10. Size, light output, emergency batteries, sensors and warranty can all affect the price. Compare fittings with similar features to judge whether the extra impact protection represents good value.
IK measures resistance to mechanical impacts; IP describes protection against the ingress of solids and water. A high IK rating does not compensate for an unsuitable IP rating. Choose a product with the right combination of protection and lighting performance for its intended location.